V300A28T500BL 300V to 28V 500W DC-DC Module Sourcing Guide
Table of Contents
- How to Read the V300A28T500BL Part Number
- Key Electrical Specifications and Operating Window
- Thermal Management and Derating
- Compliance, Screening, and Traceability
- System Integration: 28V Rails for Defense Electronics
- What to Verify Before You Buy
- Sourcing Support for the V300A28T500BL
- FAQ
- What does the BL suffix indicate?
- Is V300A28T500BL automatically a MIL-SPEC part?
- How much current can V300A28T500BL supply?
- Can I substitute a similar V300 module if it is unavailable?
- Does the module need external filtering or protection?
V300A28T500BL is a 300V nominal input, 28V output, 500W DC-DC converter in the VICOR Maxi family, specified for defense and high-reliability power distribution where a stable 28V rail must be maintained across wide input and load changes. The part is often evaluated for radar, avionics, electronic warfare, and mission-computing applications, but correct selection depends on input range, thermal management, screening, and traceability rather than the output power number alone. This guide covers the part number, operating constraints, acceptance checks, and the RFQ details that prevent a line-item match from becoming a program risk.
How to Read the V300A28T500BL Part Number
The suffix and prefix on this part carry mechanical and environmental information. Reading them correctly helps avoid accepting a pin-compatible but wrong-grade substitute.
| Field | Meaning | Why it matters |
|---|---|---|
| V300 | 300V nominal input family | Confirms compatibility with 270VDC defense buses or rectified AC front ends |
| A | Maxi-size converter family | Identifies the mechanical form factor and power class |
| 28 | Nominal 28V output | Must match the downstream rail tolerance, sequencing, and protection plan |
| T | Temperature grade | Sets the operating temperature acceptance window; verify the exact limits |
| 500 | 500W rated output | Drives current, cooling, and derating requirements |
| BL | Package and configuration suffix | Affects mounting, baseplate interface, and pinout |
Do not infer that every V300-prefix module has the same output, temperature range, or package. The final suffix letters change the mechanical and environmental acceptance.
Key Electrical Specifications and Operating Window
The V300A28T500BL belongs to VICOR’s 300V input converter family and is commonly considered for defense platforms using 270VDC or rectified AC buses. The V300 prefix does not by itself state the exact input limits, so the manufacturer’s datasheet must be used to confirm undervoltage lockout, surge response, transient behavior, and output trim.
| Parameter | Value to confirm | Relevance |
|---|---|---|
| Nominal input | 300VDC | Derived from the part number |
| Typical input range | 180 to 375VDC | Verify exact limits from the datasheet |
| Output voltage | 28VDC nominal | Trim options vary by configuration |
| Output power | 500W | Rating before thermal derating |
| Nominal output current | About 17.9A | At 28V and full rated power |
| Package | BL | Baseplate and mechanical configuration |
At 500W, the converter supplies about 17.9A at the nominal 28V output. The usable current may be lower at high case temperature, low airflow, or unusual input voltage because derating applies.
Thermal Management and Derating
For a 500W converter, the limiting factor is usually case temperature rather than the nominal output rating. The T-grade identifies a temperature window, but actual available power depends on mounting, airflow, heat sink or cold-plate design, altitude, and input conditions.
| Cooling condition | What to check |
|---|---|
| Baseplate mounting | Flatness, thermal interface material, and torque |
| Airflow | Velocity and direction across the module |
| Cold plate | Compatibility with the BL package |
| High altitude | Reduced convection and manufacturer altitude derating |
| Worst-case input | Efficiency and heat at low-line or high-line conditions |
Request thermal derating curves and apply them at the system’s worst-case input, load, and ambient condition. A module that meets the power requirement on paper can still exceed its case limit in a sealed chassis.
Compliance, Screening, and Traceability
Traceability is the decision point for a defense power module. A converter can be electrically correct but unacceptable if documentation does not support the program. Require a certificate of conformance, also called a C of C, lot and date code data, and evidence of proper handling before release.
| Documentation item | What to request |
|---|---|
| Certificate of conformance | Supplier or manufacturer C of C for the exact part number |
| Lot and date code | Manufacturing lot, date, and quantity traceability |
| Screening records | Any burn-in, electrical test, or qualification data available |
| Packaging records | ESD and moisture handling evidence |
| Substitution approval | Form, fit, and function review if a different suffix is proposed |
Do not infer a military qualification from the V300 prefix or BL suffix alone. If the program requires specific screening, qualification, or source documentation, state that requirement in the RFQ before a part is quoted.
System Integration: 28V Rails for Defense Electronics
V300A28T500BL typically feeds point-of-load converters or downstream electronics from a high-voltage bus. In a radar or electronic warfare line-replaceable unit, the module may supply regulators that power FPGAs, ADCs, processors, and low-voltage rails. Start-up inrush, remote sense, output isolation, and fault response must be planned at the system level.

For programs whose 28V rail feeds digital logic, the same BOM may include companion FPGAs. The following representative packages are co-sourced with VICOR-class power modules:




A 28V rail often feeds mission-critical FPGA boards where logic performance shapes power sequencing and inrush behavior. <XC7VX485T FPGA: Virtex-7 Performance for Defense> covers performance considerations for the defense FPGA side of the architecture.
What to Verify Before You Buy
Use the part number as a starting point, then verify the following items before the purchase becomes a design commitment.
| Check | What to request | Why |
|---|---|---|
| Full part number | V300A28T500BL exact suffix | Prevents temperature, package, or pinout substitution |
| Datasheet | Input range, trim, derating, pinout | Confirms electrical and mechanical fit |
| Traceability | C of C, lot and date code | Supports defense program acceptance |
| Inventory data | Stock, lead time, and source | Controls schedule risk |
| Incoming inspection | Visual, marking, ESD pack check | Catches handling or counterfeit issues |
| Change control | Form, fit, and function review | Prevents unapproved replacement |
Sourcing Support for the V300A28T500BL
Send your full part number, target quantity, required date, and documentation requirements to xuansc2144@gmail.com. Sparkle Electronics can check stock and lead time, confirm C of C details, and coordinate a substitute review only when the replacement matches your electrical, mechanical, and qualification requirements. If the same BOM includes FPGAs, ADCs, memory, or other hi-rel devices, include those lines for a combined availability review.
FAQ
What does the BL suffix indicate?
BL identifies the package and configuration for this Maxi module, typically associated with the baseplate mechanical form. It affects mounting, pin length, and thermal interface. Because suffix details can vary by family, confirm the exact mechanical drawing and pin list with the supplier before final release.
Is V300A28T500BL automatically a MIL-SPEC part?
No. The V300 prefix and BL suffix describe the input family and package, not a military qualification level. Whether the part meets a specific program requirement depends on the temperature grade, screening, documentation, and the manufacturer’s current datasheet. Request the exact C of C and any applicable qualification evidence.
How much current can V300A28T500BL supply?
At 28V and 500W, nominal output current is about 17.9A. The actual usable current may be lower at high temperature, low airflow, or unusual input voltage because thermal derating applies. Size conductors, connectors, fusing, and board protection for the worst-case current rather than the ideal number.
Can I substitute a similar V300 module if it is unavailable?
Do not substitute without an engineering review. V300 modules can differ in output voltage, power, temperature grade, package, pinout, and control features. If the part is unavailable, request a form, fit, and function comparison and require documented approval before accepting the replacement.
Does the module need external filtering or protection?
Most system designs add input transient protection, fusing, and output filtering to meet their own conducted emissions and load requirements. The converter datasheet provides guidance on external components, but the final input and output protection must be matched to the platform-level power quality and fault conditions.
If you’re interested, check out these related articles:
Virtex-7 XC7VX690T: Performance and Reliability Insights
XC7VX485T FPGA: Virtex-7 Performance for Defense
UltraScale KU085 FPGA Specifications for Defense Systems